Technical Parameter
Â
Rated output voltage | 0 ~ 1000kV and below |
Output frequency | 30~300Hz |
Resonant voltage waveform | Pure sine wave, waveform distortion rate ≤1.0% |
Working time | Continuous working time at full power 60min |
Quality factor | 30~90 |
Frequency regulation sensitivity | 0.1Hz |
Degree of instability | <0.05% |
Working power supply | Single-phase 220V or three-phase 380V±10% |
Power frequency 50Hz±5% |
Â
Series product configuration (Applicable scope (10kV ~ 500kV voltage level substation electrical equipment AC voltage withstand equipment, frequency 30 ~ 300Hz))
Product model | Variable frequency source | Resonant reactor | Excitation transformer | Voltage divider | Scope of application |
HTXZ-50/50 | 4kW | 25kV/1A two PCS (dry type) | 4kVA (Dry type) | 50kV | 1000kVA and below 10kV power transformer.10kV switch, bus bar, PT, CT, etc.10kV(300mm) cable ≤1.0kmundefined |
HTXZ-108/108 | 6kW | 27kV/1A four PCS (dry type) | 6kVA (Dry type) | 110kV | 31500kVA and below 35kV power transformation.35kV switch, bus bar, PT, CT, etc.10kV(300mm) cable ≤2km.undefined35kV (300mm) cable ≤0.5kmundefined |
HTXZ-200/200 | 10kW | 50kV/1A four PCS (dry type) | 10kVA (Dry type) | 200kV | 5000kVA and below 110kV power transformation.110kVGIS, PT, CT, etc. (preventive test).35kV(300mm) cable ≤1.0km. undefined10kV (300mm) cable ≤2.0kmundefined |
HTXZ-270/270 | 15kW | 45kV/1A six PCS (dry type) | 15kVA (Dry type) | 300kV | 5000kVA and below 110kV power transformation.110kVGIS, PT, CT, etc.35kV(300mm) cable ≤1.2km. undefined10kV (300mm) cable ≤3.0kmundefined |
HTXZ-800/400 | 30kW | 50kV/2A eight (dry type); undefined100kV/2A 4pcs (oil-immersed) | 30kVA (dry type); undefined30kVA (oil immersed) | 400kV | 80000kVA and below 220kV power conversion.5000kVA and below 110kV power transformation.110kV/220kVGIS, PT, CT, etc.35kV(300mm) cable ≤2.0km. undefined110kV (300mm) cable ≤0.7kmundefined |
HTXZ-1600/800 | 60kW | 200kV/2A four PCS (oil-immersed) | 60kVA (Dry type) | 800kV | 80000kVA and below 220kV power conversion.5000kVA and below 110kV power transformation.500kVGIS, PT, CT, etc.220kV switch, GIS, PT, CT, etc.110kV(400mm) cable ≤1.5km. undefined220kV (400mm) cable ≤1.0kmundefined |
Â
Nickname: AC Resonant Test Set ; Cable resonant test ; Resonant Test Set for Cable ; Resonant Test Set
Â
Â
Â
Feature
Â
1. The reactor with the same voltage grade and capacity is smaller in volume and lighter in weight; Low temperature rise at rated load; Dry pouring, high mechanical strength, good electrical insulation, beautiful and reliable.
Â
2. Frequency conversion power control box capacity margin is large; Strong protection function; Good output waveform; Good stability; With a variety of working modes, easy to operate; Single-phase 220V or three-phase 380V input power supply is universal, convenient on-site power supply.
Â
3. Flexible configuration. Different types of reactors can be selected to meet the requirements of different test products, to achieve multi-purpose, cost-effective.
Â
4. The operation interface supports language switching function, can support multi-language free switching at the same time, the default is Chinese and English switching, other languages can be customized.
Â
5. The system built-in series resonance parameter calculator, can quickly calculate the series resonance inductance, capacitance, frequency, resonant high voltage current, and cable capacity with one key.
Â
Â
Â
Â
Â
Q: What is an example of a resonant system?
A: What are some examples of resonance? Swing moves forward and backwards when pushed. If a series of regular pushes are given to the swing, its motion can be built. The person pushing the swing must sync with the swing's timing, which results in the motion of the swing having increased amplitude to reach higher.